Part Description            Wire Color            Resistance Value

Transducer supply windings on stator (wrapped)

Green to White

230 - 280 ohms

Transducer supply windings on stator (molded)

Green to White

280 - 330 ohms

Auxiliary windings

Yellow to Yellow

0.3 - 0.35 ohms

Pickup

Red to White or Ground

(old-hole) 50 - 70 ohms

Pickup

Red to White or Ground

(new-slotted) 140 - 180 ohms

Tach Wire

Grey to White

30 - 35 ohms

Transducer-Secondary windings

Plug wire to plug wire

4,800 to 6,800 ohms

Insulation of plug wire

Plug wire to ground

Open

Engine Stop Switch/Stop Position

Yellow/black to white or ground

Short

Engine Stop Switch/On Position

Yellow/black to White or ground

Open

Lighting Coil Output

3000 RPM

140W A/C

 

 

Copper wire ampacity table

Ampacities of copper wire, in free air at 30o C:

======================================================== 
|                     INSULATION TYPE:                |
|         RUW, T           THW, THWN        FEP, FEPB  | 
|           TW               RUH            THHN, XHHW | 
======================================================== 
Size    Current Rating   Current Rating   Current Rating 
AWG     @ 60 degrees C   @ 75 degrees C   @ 90 degrees C 
======================================================== 
20 -------- *9 ----------------------------- *12.5 
18 -------- *13 ------------------------------ 18  
16 -------- *18 ------------------------------ 24  
14 --------- 25 ------------- 30 ------------- 35  
12 --------- 30 ------------- 35 ------------- 40  
10 --------- 40 ------------- 50 ------------- 55  
8 ---------- 60 ------------- 70 ------------- 80  
6 ---------- 80 ------------- 95 ------------ 105  
4 --------- 105 ------------ 125 ------------ 140  
2 --------- 140 ------------ 170 ------------ 190  
1 --------- 165 ------------ 195 ------------ 220  
1/0 ------- 195 ------------ 230 ------------ 260   
2/0 ------- 225 ------------ 265 ------------ 300  
3/0 ------- 260 ------------ 310 ------------ 350  
4/0 ------- 300 ------------ 360 ------------ 405  

* = estimated values; normally, wire gages this small are not manufactured with these insulation types.

 